Reproducibility of isometric strength: measurement of neck muscles
1999
Abstract Objective. To evaluate the repeatability of an advanced method of measuring the strength of functionally different groups of neck muscles using an isometric apparatus. Design. A repeated measures design was used within and between sessions. Background. Chronic neck pain has been associated with poor isometric neck strength. In rehabilitation, strength measurements may thus help to evaluate the basic condition and show whether or not treatments and exercises have been beneficial for improving strength. Previous tests have concentrated on testing strength while trying to bend forwards and backwards, but no biomechanics device, able to test rotator muscles, has been presented. Method.…
Comparison of single-spot technique and RGB imaging for erythema index estimation
2016
A commercially available point measurement device, the Mexameter(®), and an experimental RGB imaging prototype device were used for erythema index estimation of 50 rosacea patients by analysing the level of skin redness on the forehead, both cheeks and both sides of a nose. Results are compared with Clinician's Erythema Assessment (CEA) values given by two dermatologists. The Mexameter uses 568 nm and 660 nm LEDs and a photodetector for estimation of erythema index, while the used prototype device acquired RGB images at 460 nm, 530 nm and 665 nm LED illumination. Several erythema index estimation algorithms were compared to determine which one gives the best contrast between increased eryth…
Effects of soil gas permeability and recirculation flux on soil CO2 flux measurements performed using a closed dynamic accumulation chamber
2009
Abstract Dynamic accumulation chamber methods have been extensively used to estimate the total output of CO2 released from active volcanic area. In order to asses the performance and reliability of a closed dynamic system several tests were carried out with different soil permeabilities and soil CO2 fluxes. A special device was used to create a constant one-dimensional CO2 flux through a soil column with a known permeability. Three permeabilities were investigated, ranging between 3.6 × 10− 2 and 3.5 × 10 μm2, as were several CO2 fluxes (ranging between 1.1 × 10− 6 and 6.3 × 10− 5 kg m− 2 s− 1). The results highlight that the accuracy of soil CO2 flux measurements strictly depends on the so…
Optical sensor for remote estimation of alcohol concentration in blood stream
2013
Abstract The purpose of this manuscript is to validate our recently developed novel optical approach for extraction of remote vibration sources as a successful technique to estimate the alcohol concentration in blood stream. This technique is based on the tracking of temporal changes of reflected secondary speckle patterns produced in human skin when being illuminated by a laser beam. Since the skin’s vibrations profile is changed due to the alcohol in the blood stream, the extraction of the vibration profile can be translated into the corresponding alcohol concentration values by means of defining several parameters acting as indicators for the presence of alcohol in the blood stream. We h…